New product
Electronic Ballast Unit EVG UV 12-25 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 1-phase or 2 phase
+ Simple mounting
+ External ignitor required
+ Compact and lightweight
The EVG UV 12-25 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 0.4 kW – 1,2 kW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps of 5 – 25 cm (2” – 10”) arc length. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a square-wave current. Principle of function of the electronic ballast unit EVG UV 12-25 AC is an adjustable constant current source in the range of 2 A to 14 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value. Within a nominal lamp voltage of 95 V to 130 V and depending on the type of lamp and type of cooling the following lamp power is possible:
300 W to 1.200 W infinitely variable from approx. 15% to 100%
Electronic Ballast Unit EVG UV 20-42 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 1-phase or 2 phase
+ Simple mounting
+ External ignitor required
+ Compact and lightweight
The EVG UV 20-42 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 0.5 kW – 2 KW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps of 5 – 45 cm (2” – 17”) arc length. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a square-wave current.Principle of function of the electronic ballast unit EVG UV 20-42 AC is an adjustable constant current source in the range of 1,5 A to 13 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value.
Within a nominal lamp voltage of 100 V to 300 V and depending on the type of lamp and type of cooling the following lamp power is possible:
300 W to 2.000 W infinitely variable from approx. 15% to 100%
Electronic Ballast Unit EVG UV 21-42 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 1-phase or 2 phase
+ Simple mounting
+ No external ignitor required
+ Compact and lightweight
The EVG UV 21-42 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 0.5 kW – 2 KW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps of 5 – 45 cm (2” – 17”) arc length. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a square-wave current. Principle of function of the electronic ballast unit EVG UV 21-42 AC is an adjustable constant current source in the range of 1,5 A to 13 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value.Within a nominal lamp voltage of 100 V to 300 V and depending on the type of lamp and type of cooling the following lamp power is possible:
300 W to 2.000 W infinitely variable from approx. 15% to 100%
Electronic Ballast Unit EVG UV 26-70 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 1-phase, symmetrical mains connection
+ Simple mounting
+ No external ignitor required
+ Compact and lightweight
The EVG UV 26-70 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 1.0 kW – 2.6 kW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps of 15 – 70 cm (6” – 27”) arc length. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a square-wave current.
Principle of function of the electronic ballast unit EVG UV 26-70 AC is an adjustable constant current source in the range of 1,5 A to 15 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value.
Within a nominal lamp voltage of 100 V to 450 V and depending on the type of lamp and type of cooling the following lamp power is possible:
300 W to 2.600 W infinitely variable from approx. 10% to 100%
Electronic Ballast Unit EVG UV 36-70 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 3-phase, symmetrical mains connection
+ Simple mounting
+ No external ignitor required
+ Compact and lightweight
The EVG UV 36-70 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 3 kW – 6 kW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a square-wave current. Principle of function of the electronic ballast unit EVG UV 36-70 AC is an adjustable constant current source in the range of 1,5 A to 15 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value. Within a nominal lamp voltage of 100 V to 450 V and depending on the type of lamp and type of cooling the following lamp power is possible:
600 W to 6.000 W infinitely variable from approx. 10% to 100%
Electronic Ballast Unit EVG UV 49-70 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 3-phase, symmetrical mains connection
+ Simple mounting
+ No external ignitor required
+ Compact and lightweight
The EVG UV 49-70 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 4 kW – 9 kW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps of 15 – 70 cm (6” – 27”) arc length. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a square-wave current.
Principle of function of the electronic ballast unit EVG UV 49-70 AC is an adjustable constant current source in the range of 2,2 A to 22 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value.
Within a nominal lamp voltage of 100 V to 450 V and depending on the type of lamp and type of cooling the following lamp power is possible:
900 W to 9.000 W infinitely variable from approx. 10% to 100%
Electronic Ballast Unit EVG UV 62-70 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 3-phase, symmetrical mains connection
+ Simple mounting
+ No external ignitor required
+ Compact and lightweight
The EVG UV 62-70 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 6 kW – 12 kW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps of 15 – 70 cm (6” – 27”) arc length. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a square-wave current. Principle of function of the electronic ballast unit EVG UV 62-70 AC is an adjustable constant current source in the range of 2,8 A to 28 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value.
Within a nominal lamp voltage of 100 V to 450 V and depending on the type of lamp and type of cooling the following lamp power is possible:
1.200 W to 12.000 W infinitely variable from approx. 10% to 100%
Electronic Ballast Unit EVG UV 63-105 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 3-phase, symmetrical mains connection
+ Simple mounting
+ No external ignitor required
+ Compact and lightweight
+ Ignites “bad starter” lamps
The EVG UV 63-105 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 6 kW – 12 kW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps of 30 – 105 cm (12” – 41”) arc length. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a squarewave current. Principle of function of the electronic ballast unit EVG UV 63-105 AC is an adjustable constant current source in the range of 3,0 A to 30 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value.Within a nominal lamp voltage of 100 V to 700 V and depending on the type of lamp and type of cooling the following lamp power is possible:
1.200 W to 12.000 W infinitely variable from approx.10% to 100%
Electronic Ballast Unit EVG UV 89-140 AC
+ Infinitely variable lamp power
+ Automatic constant regulating
+ Quick pulsing of lamp power
+ Automatic constant lamp power
+ 3-phase, symmetrical mains connection
+ Simple mounting
+ No external ignitor required
+ Compact
The EVG UV 89-140 AC is a fully electronic, adjustable AC ballast unit for UV-lamps from approx. 8 kW – 20 kW nominal power and specially designed for industrial use. It is specially tuned to operate with mercury discharge UV-lamps of 50 – 140 cm (20” – 55”) arc length. Dark phases during the zero axis known from standard, sinus shaped power supplies are eliminated by operating the lamps with a squarewave current. Principle of function of the electronic ballast unit EVG UV 89-140 AC is an adjustable constant current source in the range of 3 A to 25 A. The lamp power is regulated to a constant value by an internal regulation unit through an external DC 0 – 10 V rated value. Within a nominal lamp voltage of 800 V to 900 V and depending on the type of lamp and type of cooling the following lamp power is possible:
2.500 W to 20.000 W infinitely variable from approx. 10% to 100%
Download Datasheet:
evg12-25.pdf
Download Datasheet:
evg20-42.pdf
Download Datasheet:
evg21-42.pdf
Download Datasheet:
evg26-70.pdf
Download Datasheet:
evg36-70.pdf
Download Datasheet:
evg49-70.pdf
Download Datasheet:
evg62-70.pdf
Download Datasheet:
evg63-105.pdf
Download Datasheet:
evg89-140.pdf
This product is no longer in stock
Warning: Last items in stock!
Availability date:
-->