UV-4C MICROPROCESSOR INTEGRATOR is a self-contained, high quality UV measuring instrument. It is designed to measure, record and display peak UV intensity and UV dosage in the UV curing process.
+ UV-A intensity mW/cm + UV-A dose mJ/cm
+ UV-B intensity mW/cm + UV-B dose mJ/cm
+ UV-C intensity mW/cm + UV-C dose mJ/cm
+ UV-V intensity mW/cm + UV-V dose mJ/cm
+ Full UV intensity mW/cm + Full UV dose mJ/cm
+ Permanent or "triggered measuring mode*
+ Re-chargeable accu cells with charger
It is equipped with four different UV sensors for the individual measuring of
UV-A 315 410 nm
UV-B 280 315 nm
UV-C 230 280 nm
UV-V 395 445 nm
UV - 250 410 nm
With these four different UV-bands all of the measuring requirements of UV curing applications can be covered.
Due to its four different UV sensors and the integrated microprocessor the UV-4C can measure, record and display the peak of the UV-energy (mW/cm2) for each UV-band individually plus the peak of total UV energy.
Additionally, this UV-Integrator is calculating the UV-dosage (mJ/cm2) of the UV energy supplied during the time of exposure of one measuring cycle. The UV-dosage is calculated for each UV-band (UV-A, UV-B, UV-C and UV-V) individually and as total Integral of UV-dosage over all three UV-bands. This allows to determine not only the total energy, but also how that energy is delivered, i.e., what intensity and dose at what UV-band.
The four sensors are on the back of the unit which also serves as a heat shield. After completion of the measuring cycle all measuring results can be scrolled through on the built in 2 x 16 digit LCD display.
A special AUTO-OFF feature that turns off the unit automatically after one minute serves as energy saving and extension of the battery service life.
*This Microprocessor Integrator features a selectable triggered mode, i.e. the 30 sec recording cycle starts within a 120 second readiness phase not before the incident UV-intensity exceeds 2 mW/cm.
As an option, this microprocessor integrator is available with an USB ComPort and an evaluation software for downloading the data to a computer to show, edit and store a history of the measuring results of the entire measuring cycle as graphic charts (mW/cm2) and (mJ cm2) and (C/F)
TECHNICAL DATA
Spectral ranges:
UV-A 315 410 nm
UV-B 280 315 nm
UV-C 230 280 nm
UV-V 350 460 nm
UV 230 410 nm
Max. Power Input 0 to 5,000 mW/cm2
Measuring range: 0 to 2,000 mW/cm2
Sampling rate: 0.005 sec (200/sec)
Recording cycle: 30 sec.
Readiness phase: 120 sec.
Display range: 0 to 36,000 mJ/cm2
Display: LCD, 2 x 16 digits
Power source: 2 x 3.7 V LiPO Accu
Power consumption: 20 A
Accu service life: 1,000 re-charging cycles
Dimensions: 5.5 (140 mm), height (13 mm)
Weight: approx. 17.5 ounce (500 g)
Operating temperature: 32 to 113 F / 0 to 45 C
Heat protection: Heat shield on back plate
Base Accuracy: 5 %
While on the conveyer belt, the UV-4C Microprocessor Integrator can withstand max. 230 F / 110 C for up to 10 seconds. The temperature of the housing should not exceed 113 F / 45 C. Because of uneven radiation distribution of the UV light source and different type of construction of the measuring devices by different manufacturers, different readings may appear under the same measurement conditions.
CALIBRATION
In order to keep its full function and precision it is recommended to have re-calibration done once per year. Re-calibration will also be necessary after change of battery. PTB traceable calibration acc. to DIN EN ISO / IEC 17025 with certificate