Ask A Question - email us at info@uvps.com
UV Literature Forms Data Sheets UVPS International Representatives

UV Lamps

UV Lamps

UV Process Supply Home Page

Help Me Find It! - email us at info@uvps.com

The Complete Source
For All Your
UV Curing Needs!

Microwave Parts, Lamps magetrons, screens, ignigtor bulbs
Microwave Parts

Safety Products- Gloves, Hand Cleaner, Eye protection, Full Body protection Ink & Coating Handling: Storing, Mixing, Dispenisng, Measuring Maintenace & Shop: Clean-Up Supplies, Shop Supplies, Shop Lighting, Static Control, Shop Safety, Equipment Maintenance. Curing Controls: Speed Monitors, Temperature & Air Monitors, UV Radiation Dose Monitors, Degree of Polymerization, Film Thickness Controls, Physical Test Equipment, UV Inspection. Curing Equipment: Laboratory Curing Equipment, Small Area Curing Equipment, Low Intensity UV Lamps, Replacement UV Lamps, UV Curing Equipment. Printing Supplies: Screen Printing Supplies, Squeegee and Accessories, Applicators, Screen Making Supplies, Screen Cleaning Supplies, Offset Printing Supplies, Graphic Arts Supplies, Color Inspection, Pantone Products, Bench Magnifiers, Folding Magnifiers, Lighted Magnifiers, Swivel-Arm Magnifiers, Microscopes, Graphic Arts Supplies.
Safety Products Ink Coating & Handling Maintenance & Shop Curing Controls Curing Equipment Printing Supplies
LOGIN MENU ORDER TRACKING YOUR ORDER
CheckoutORDER CHECKOUT

AIR FLOW DATA SAMPLERS I D AND IID
 

Back to : HOME : CURING CONTROLS: D3 UV MEASUREMENT : RADIOMETERS SPECIAL TYPES

 


Download Datasheet:
VOC DATA SAMPLER 822.PDF


Download Support Document:
Measuring UV-Terms and Help.pdf

   

 
AIR FLOW DATA SAMPLERS I D AND IID

The VOC DATA SAMPLERS are a portable, pass-through, Pocket-PC based data logger for IR, convection and other heat curing systems using solvent containing inks, glues, lacquers and paints.



+ up to 4 channels
+ solvent residues in ppm*
+ air-flow measuring (option)
+ temperature measuring (option)
+ pass-through data acquisition
+ built-in sensors
+ computer programmable
+ parameter selection
+ auto scale function
+ Free selectable areas
+ Graphic charts on PC via ComPort
+ Result storing capability on PC via ComPort
+ Data Acquisition Software

It is detecting organic solvent vapours, other volatile vapours and combustible gases such as carbon monoxide, ethanol, isobutanes, n-hexanes, benzenes, ethanol, acetone etc. Due to its compact dimensions and heat resistance up to 200C (with optional carrier) it is ideal to be used in conveyorized thermal curing ovens typically used in the printing, semiconductor and wood industry. Via ComPort, it is connected to a PC in order to pre-select parameters for the measuring cycle. After passage of the curing chamber the recorded data can be downloaded to a computer for further editing by a Powerful Data Acquisition Software. The measurement and recording of data takes place at user-defined intervals. In the basic version the VOC Data Sampler 822 is equipped with one solvent detection sensor.

The solvent detection sensor has a high sensitivity to the vapours of organic solvents as well as other volatile vapours. It has also sensitivtiy to a variety of combustible gases. Precise temperature measuring is made possible by a fast response temperature sensor (option). An air-flow sensor is optionally available. The sensors are built in the housing and the back of the unit serves as a heat shield. Extra heat protection up to 200C with separately available carrier (option). The measuring results are displayed on graphs and show the solvent concentration in ppm as well as the temperature curve during the measuring cycle in C. The monitor displayed graphs show the complete profile and offer zooming and auto scale functions. Measuring values are also displayed as digital numbers. The following versions are available:

VOC Data Sampler 822 Basic
VOC Data Sampler 822 with temperature sensor
VOC Data Sampler 822 with air flow sensor
VOC Data Sampler 822 with temperature sensor and air flow sensor
The powerful evaluation software is included and enables the user to synchronise the VOC Data Sampler 822 with a PC via RS232

TECHNICAL DATA
Detected agents : Solvents, Vapours, Gases such as: carbon monoxide, ethanol, isobutanes, n-hexanes, benzenes, ethanol, acetone etc.
Measuring range: 0 to 5,000 ppm
Measuring range: 32 to 392 F / 0 to 200 C
Sample rate: 0.1 sec
Power source: 8 x 1.5 V rechargeable Battery
Power consumption: 350 mA
Battery service life: 1,000 reloads
Dimensions: approx. 5.8 x 7 x 0.8 (147 x 180 x21 mm)
Weight: approx. 17.5 ounce (450 grs.)
Temperature range: 32 to 113 F / 0 to 45 Centigrade
Heat protection: heat protection with separately available carrier (option)
Base Accuracy: 5 %

With the optionally available heat protection carrier, the VOC Data Sampler 822 can withstand max.
110/200 C / 230/392 F for up to 30 seconds. The temperature of the housing should not exceed 45Centigrade.

CALIBRATION
In order to keep its full function and precision it is recommended to have re-calibration done once per year. Re-calibration will also be necessary after change of battery.
response.write virtual="/inc_files/DisplayImageAndTextFiles.asp"
ORDERING INFORMATION
Part No.Desc.PriceOrder
M007-590RADM VOC DATA SAMP I$6,966.00 / EACHorder now
M007-591RADM VOC DATA SAMP I$7,328.00 / EACHorder now
M007-592RADM VOC DATA SAMP I$9,002.00 / EACHorder now
M007-593RADM VOC DATA SAMP 822$9,452.00 / EACHorder now
M007-594RADM AIR FLOW DATA SAM$6,616.00 / EACHorder now
M007-595RADM AIR FLOW DATA SAM$8,506.00 / EACHorder now
M007-596RADM AIR FLOW DATA SAM$9,020.00 / EACHorder now
M007-597RADM AIR FLOW DATA SAM$9,470.00 / EACHorder now
M007-598RADM AIR FLOW DATA SAM$10,270.00 / EACHorder now
M007-599RADM AIR FLOW DATA SAM$10,708.00 / EACHorder now
M007-600RADM AIR FLOW DATA SAM$10,930.00 / EACHorder now
M007-601RADM AIR FLOW DATA SAM$1,640.00 / EACHorder now


Not what you are looking for? Try other RADIOMETERS SPECIAL TYPES, such as:

CON-TROL CURE UV SENSORS

MICRO PUCK (SERIES) RADIOMETER

MICROCURE RADIOMETER

 

See ordering information below

 
PRICE QUOTE - email us at quotes@uvps.com




'
           
UVPS HomePage Who We Are - About UV Process Supply Jobs at UV Process Supply Sales Items at UVPS   Contact Us
           
UV Process Supply

1229 W. Cortland St.  Chicago, IL 60614-4805  Phone: 1-800-621-1296 OR 773-248-0099  Fax: 1-800-99FAXUV OR +1-773-880-6647 Email: info@uvps.com
COPYRIGHT 2011 U V Process Supply, Inc. * Call us on Skype "uvprocess"